This line of analyzers adds much more functionality and
customizability compared to the 050 model, yet retains similar portability
features. View the additional and optional features in the specifications
box to see all of the enhancements.
DILLUTION FILTER
On the 100 model line of analyzers it is possible to achieve
a 0-100% detection range with a specially designed dillution filter. This
is currently the only available (other dillution methods are available on
400 models and higher) model with this dillution system as an option.
PRESSURE REGULATOR
This device is used to reduce a high pressure, supply pressure,
or inlet pressure in one stage to a lower pressure. The pressure reducing
regulator is designed to meet the stringent requirements of a process analyzer
sample conditioning system. The low internal volume reduces lag time thus
more nearly approaching real-time analysis.
SAMPLE FILTER
This device is used to remove unwanted contamination in
a system. Bypass filters allow a continuous sweeping action across the surface
of the filter element. This sweeping action prolongs the life of the filter
element and also insures the sample that passes through the element is representative
of the current system condition.
CAL TAP
The calibration tap point includes the connection fittings
and tubing together with a three-way ball valve to easily connect calibration
gas to the analyzer.
DIAGNOSTIC ALARM
The alarm provides contact output to alert operations in
the event of one of the following fault conditions:
- Out of tape
- Motor failure
- Optical system failure
- Auto Calibration failure
SMARTALK
SMARTalk provides complete remote operation via personal
computer or host with true bidirectional communication. The operator does
not have to travel to the measurement site to alter operation, initiate
calibration, or view data. Controls, reports, and data are available at
lab or office via a personal computer link. Remote access reduces the chance
of "no fault found" service calls where on site trips find no
fault with the equipment.
LCD GRAPH DISPLAY
The display is a paperless chart recording of the concentration
with selectable time scale to make comparisons and graphically display operating
trends over time.
SAMPLE PUMP
A miniature DC powered rotary vein pump to provide sample
flow from atmospheric sources. This option is necessary if there is no line
pressure.
CABINET HEATER
A heater with thermostat control is integrated into the
cabinet which provides freeze protection throughout the cold winter months.
This will prevent the humidifier solution from freezing in sub zero temperatures
causing the unit to malfunction. This will drop the lowest allowable operating
temperature 15°C to -10°C.
VAPORIZING REGULATOR
The vaporizing regulators vaporize a liquid into a gas
then perform a single stage pressure reduction on the gas. Pressure drops
through pressure regulators may cause cooling which allows liquid to form.
The vaporizing regulator puts heat back into the flow media to insure that
is stays a gas.
CHART RECORDERS
A hard copy record of 4-20 mA output is available in:
- General Purpose / Division II
- Division I
AUTO CALIBRATION
The auto calibration provides software algorithm, contact
outputs, solenoid valves, tubing, and customer connections for automatically
calibrating analyzer at preselected time intervals.
Battery Power
The Trace 100 model line of analyzers can be supplied with
an optional battery power supply to complete remote operation. This feature
is available on the 050 model line also! |
 |
DISPLAY
- Alpha Numeric LCD
- 128 x 64 pixel
TEMPERATURE RANGES
- -10°C to 50°C (operating)
- 0°C to 70°C (storage)
ANALOG - Isolated 4-20 mA
ANALYTICAL PERFORMANCE
- Resolution: 1 ppb
- Accuracy: ±2%
- Repeatability: ±1%
- Linearity:±1%
- Drift: Nil
- Temp. Coefficient: 0.01% / °C
- Analysis Time: 0.75 Second
- Detection Ranges:
0-1 ppm
0-50 ppm
0-500 ppm
AREA CLASSIFICATION
WEIGHT - Approx. 20 lbs; 9 kg
DIMENSIONS
- 14" X 16" X 8"
POWER
REQUIRED
- 110VAC, 60 Hz or
- 220VAC, 50 Hz or
- 12VDC, or
- 24VDC
ADDITIONAL FEATURES
(compared to the previous model)
- Pressure Regulator
- Cal Tap
OPTIONAL FEATURES
(features not optional on previous model are
bold)
- Battery Power
- SMARTalk
- LCD Graph Display
- Sample Filter
- Dilution Filter
- Diagnostic Alarm
- Auto Calibration
- Sample Pump
- Cabinet Heater
- Vaporizing Regulator
- Chart Recorders
- Cabinet Stand
- Remote Display and Alarms
- TRACErase
- Solar Power
- Multi Stream
|
CABINET STAND
The cabinet stand is a pipe stand with mounting holes for
outdoor and indoor use.
TRACERASE
TRACErase uses technology based on a catalytic combustion
process to oxidize vented samples thus preventing fugitive emissions from
entering the atmosphere without causing back pressure on the analyzer. Packaged
to provide explosion proof protection, this unit may be used in hazardous
locations.
SOLAR POWER
This option includes batteries, a solar panel, and charge
control to maintain analyzer operation in remote locations
REMOTE DISPLAY AND ALARM
This option uses the 4-20 output from the analyzer to generate
a digital display of concentration and adjustable alarm contact outputs
MULTI-STREAM
This option allows the analyzer to select and analyze more
than one sample source. This is ideal for any situation where more than
one sample source is present.
BACK-LIT DISPLAY
A new option available on the TRACE analyzer
is a light behind the LCD to make operation even more user friendly. |