| PUSH
BUTTON CALIBRATION
The power and flexibility of the Trace microprocessor-based
analysis system are available at the touch of a button to help operators
with one of their most important responsibilities . . . Calibration. The
microprocessor, when requested, selects references, performs calculation
adjustments, and verifies faster and more precisely than even the most
experienced operators. The unique Trace internal calibrator permits push
button selection to quickly and easily verify operation.
ASTM REFERENCE
METHODS
The field proven Trace microprocessor technology has been
combined with ASTM approved analytical methods. The reference methods are:
ASTM D4084-82
ASTM D4468-85
ASTM D4045-81
The detection technology is based on chemically specific
density changes. Optical illumination and detection are integrated for
maximum resolution accuracy. Microprocessor technology is combined with
statistical software algorithms to calculate precision analysis results.
WORD
MENU DISPLAYS
Plain language displays with descriptions of operation
status support easy use. The 128 x 64 pixel LCD display allows selections
to be displayed in plain language: English, Spanish and other languages.
The operator can make selections from available menu choices. This allows
the operator to become familiar with the instrument much faster than with
other forms of interaction.
DUAL
MICROPROCESSORS
Two independently functioning microprocessor systems are
embedded in the Trace analyzer architecture. This dual processor structure
allows one processor to have uninterrupted dedicated execution of the analysis
algorithms. The second processor is dedicated to the user friendly interaction
and display. Dual processor design ensures continuous precision analysis
and dedicated responsive communication with interactive displays. Embedding
two microprocessors in the system electronics allows each processor to
have a single first priority. One is dedicated to easy, clear, and responsive
information display and operator interaction; the other processor is dedicated
to precision analysis calculation without interruption for communication
requests.
TANGENT
SAMPLE FLOW
Sample flow is tangent to the Trace Tape to eliminate
effect from porosity variations when sample is passed through the tape.
Signal generation is based on H2S concentration only. Therefore, the sample's
volumetric flow rate does not affect accuracy.
LEAD
ACETATE DETECTOR
The only detection method that is absolutely specific
to hydrogen sulfide. Based on the formation of lead sulfide when lead acetate
tape is exposed to the H2S sample through and aperture in the sample flow
system. This system is totally specific to sulfur. It is unaffected by
the composition of the carrier or sample gas. Since the product of the
reaction of lead acetate and H2S is colored and the reactants are not,
the progress of the reaction is easily monitored. The rate of formation
of lead sulfide may be determined by measuring the rate of the tape darkening.
Rate of tape darkening is linear with respect to H2S concentration.
18 BIT
A/D CONVERSION
Allows the detection and resolution of smaller signal
values. This means that lower levels of H2S can be detected. The greater
dynamic range of counts up to 262,144 means a wider range of H2S concentration
can be measured without recalibration.
POWER
SWITCH
Convenient on/off control for the analyzer |
DIGITAL
ELECTRONICS
Digital electronics takes full advantage of microprocessor
calculation precision. Data is acquired with 18 bit conversion resolution.
Signal over sampling is applied for statistical detection processing and
accuracy correlation. An extensive set of mathematical algorithms are executed
with full floating point precision to calculate the concentration analysis.
FIELD PROVEN
Operator confidence has been earned through exceptional
on-line performance. Reliable operation is an absolute requirement for
acceptable performance. Field proven performance is your assurance that
reliability is built into Trace Technology products at every level from
initial design to final calibration. Performance is your assurance of hassle-free
compliance certification. Documented verification of accurate, stable results
over an extended, uninterrupted period of operation is required to earn
certification. Trace Technology systems have earned certification even
in the most aggressive environments.
EASY
INSTALLATION
User friendly starts with easy installation. Gas line
connections on the outside of the analyzers are labeled for easy setup.
Straight-forward ease of installation allows operators to start recording
accurate readings almost immediately. Easily accessible sub-assemblies
and components support user configuration changes, troubleshooting analysis,
and validation checks.
FAULT
TOLERANT OPERATIONS
Fault tolerant diagnostics are your assurance of low stress
operation. The Trace Technology system architecture provides extended maintenance
tools, such as fault code logging, calibration records and analysis logs,
status displays, and many other selections of data. Even after a total
power failure, the analysis is fully operational as soon as power is returned
to the unit.
PHOTO
DETECTOR
The primary detection sensor is a silicon based photo
voltaic device that does not have the performance decay associated with
photo resistive detection devices.
STATUS
REPORT LOG
At any point in time the operator can select to view current
operation status on the analyzer status page.
LED LIGHT
SOURCE
The analysis illumination light source is a high efficiency
LED which does not have the stability and aging problems associated with
incandescent light sources.
TEMPERATURE
COMPENSATION
Trace information processing algorithms completely eliminate
the effect of parameter offsets commonly referred to as drift. Any effect
of temperature on the system amplifier gain is compensated by the use of
internal reference measurements made at the beginning of each tape advance
cycle. These reference measurements are used to normalize signal processing.
SWEPT
VOLUME HUMIDIFIER
The humidification contact chamber is a 1/8" tube path
that is continuously swept as the sample flows. This eliminates any dead
volume which would affect reading accuracy and system response.
OPERATOR
KEYPAD
A directly accessible six-function operator keypad allows
configuration selection, maintenance control, and operation setup to be
quickly and easily executed.
STATUS
DISPLAY PAGES
Menu selection that displays current operating status
to the unit. |